clima DL-110

LON Universal room controller

Description

The clima DL-110 is a universal room controller. It is suitable for controlling static heating/cooling systems (like radiators, heated/chilled ceilings, chilled beams) and fan coil systems. Here the usage of 2-pipes, 3-pipes and 4-pipes-system are supported.

Additionally wall modules with temperature sensor, humidity sensor and push buttons for setpoint and fanspeed adjustment can be connected as well as a multisensor for presence detection, for measurement of ambient brightness in rooms and as receiver for the infrared remote control with LC display dialog DRC-10.

An LNS plug-in for comfortable configuration is available.

Available inputs and outputs

The inputs and outputs listed in the following table can be freely configured.

Type Number Usage
Analog input 0-10V 1 e.g. Air quality sensor
Analog input für NTC 10kOhm 2 Temperature sensor
Digital input for floating contacts 4 e.g. Window contact, dew point sensor, hotel card switch
Analog output 0-10V 2 e.g. Valve or damper actuator, fan
Digital output 24 VDC 2 e.g. Valve actuator (2-point and 3-point)
Fan output 230 VAC (max. 3-stage) 1 Fan
Switching output 230VAC 1 e.g. Heater battery, contactor (relay) for central-off

Supported heating/cooling systems

The heating/cooling systems listed below are supported by clima DL-110. Thereby the required actuators can be freely assigned to the available outputs.

  • Heating with radiator
  • Heating with radiator, air quality control with VAV
  • Heating with radiator, cooling and air quality control combined with VAV
  • Cooling with chilled ceiling
  • Cooling with chilled ceiling, air quality control with VAV
  • Cooling with chilled ceiling, heating and air quality control combined with VAV
  • Cooling with chilled ceiling, heating with radiator
  • Cooling with chilled ceiling, heating with radiator, air quality control with VAV
  • Heating and cooling with combined heated/chilled ceiling (2-pipe system)
  • Heating and cooling with combined heated/chilled ceiling (2-pipe system), air quality control with VAV
  • Heating and cooling with combined heated/chilled ceiling (4-pipe system, 4 valves)
  • Heating and cooling with combined heated/chilled ceiling (4-pipe system, 4 valves), air quality control with VAV
  • Heating and cooling with combined heated/chilled ceiling (4-pipe system, 3 valves)
  • Heating and cooling with combined heated/chilled ceiling (4-pipe system, 3 valves), air quality control with VAV
  • Heating and cooling with combined heated/chilled ceiling (4-pipe system, 6-way valve)
  • Heating and cooling with combined heated/chilled ceiling (4-pipe system, 6-way valve), air quality control with VAV
  • Cooling with fan coil
  • Cooling with fan coil, air quality control with VAV
  • Cooling with fan coil, heating and air quality control combined with VAV
  • Cooling with fan coil with outdoor air damper (incl. air quality control)
  • Cooling with fan coil, heating with radiator
  • Cooling with fan coil, heating with radiator, air quality control with VAV
  • Cooling with fan coil with outdoor air damper (incl. air quality control), heating with radiator
  • Heating with fan coil
  • Heating with fan coil, air quality control with VAV
  • Heating with fan coil, cooling and air quality control combined with VAV
  • Heating with fan coil with outdoor air damper (incl. air quality control)
  • Heating and cooling with fan coil (2-pipe system)
  • Heating and cooling with fan coil (2-pipe system), air quality control with VAV
  • Heating and cooling with fan coil with outdoor air damper (2-pipe system), incl. air quality control
  • Heating and cooling with fan coil (4-pipe system)
  • Heating and cooling with fan coil (4-pipe system), air quality control with VAV
  • Heating and cooling with fan coil with outdoor air damper (4-pipe system), incl. air quality control

For supporting not listed heating/cooling systems please contact our support. Please find the contact information at the end of this data sheet.

Technical Data

Network TP/FT-10 (FTT10)
Power supply 230V AC, max. 10A
Inputs 2 x RJ9 for DWM-xx and DMS-20
2 x NTC10k for temperature
1 x 0-10V e.g. for CO2, VOC
4 x DI for floating contacts
Outputs 1 x 230V AC, 8A for el. heater
3 x 230V AC, 2A for fan
2 x 0-10V for actuators or fans
2 x 24V DC for therm./mot. act.
Metrics (HxWxD) 102(63) x 140 x 52mm
Mouting DIN rail mounting or with srew holes

Ordering Information

Order No. 331 110